1 Bedrooms 1 Bathrooms Peak Flow: 3.5 GPM (13.2 L/min) 1 - 2 People

Tankless Water Heater Sizing for 1 Bedroom, 1 Bathroom Home

A standard 1 bedroom, 1 bathroom home requires a peak hot water capacity of 3.5 GPM to support 1 simultaneous shower plus concurrent kitchen or laundry fixtures. Compare with our Tankless Sizing Chart and master Water Heater Sizing Calculator.

Sizing Inputs

Demand Engine
Groundwater & Target Temperatures ΔT Formula
Groundwater:
°F
°F (Code: 120°F)
Simultaneous Peak Fixtures Active Rush
Qty
GPM
Qty
GPM
Qty
GPM
Qty
GPM
Qty
GPM
Qty
GPM
SIZING RECOMMENDATION

Tankless Capacity

Required Peak Flow Rate
6.0 GPM
at 70°F Temperature Rise
Metric: 22.7 L/min at 38.9°C Rise
Heating Power 210,000 BTU/hr 61.5 kW
Groundwater ΔT 70°F 50°F → 120°F
Electrical Service 256 Amps 240V Dedicated

Your peak simultaneous hot-water demand is 6.0 GPM (22.7 L/min) with a 70°F (38.9°C) temperature rise (incoming 50°F → desired 120°F). To deliver this flow reliably, your Gas tankless heater must produce approximately 210,000 BTU/hr (61.5 kW). Ensure the chosen model provides at least 6.0 GPM at a 70°F rise.

Recommended Models Matches Load
RINNAI Rinnai RX199iN / RXP199iN
5.5 GPM @ 70°F
Power: 199,000 BTU/hr UEF: 0.98 UEF Fuel: GAS

Best for large households (3-4 simultaneous showers in cold climates).

RINNAI Rinnai RX160iN
4.4 GPM @ 70°F
Power: 160,000 BTU/hr UEF: 0.97 UEF Fuel: GAS

Ideal for standard 2-3 bathroom homes with moderate to cold groundwater.

RINNAI Rinnai RX130iN
3.6 GPM @ 70°F
Power: 130,000 BTU/hr UEF: 0.96 UEF Fuel: GAS

Ideal for 1-2 bathroom homes or warmer climate zones.

RINNAI Rinnai V65iN
3.8 GPM @ 70°F
Power: 150,000 BTU/hr UEF: 0.82 UEF Fuel: GAS

Cost-effective non-condensing gas solution for small-to-medium demand.

RHEEM Rheem RTGH-95DVLN
5.3 GPM @ 70°F
Power: 199,900 BTU/hr UEF: 0.93 UEF Fuel: GAS

High-output gas unit supporting up to 3-4 simultaneous showers.

RHEEM Rheem RTGH-84DVLN
4.7 GPM @ 70°F
Power: 180,000 BTU/hr UEF: 0.93 UEF Fuel: GAS

Efficient mid-size whole-house gas tankless for 2-3 bathrooms.

RHEEM Rheem RTEX-27 (240V)
2.6 GPM @ 70°F
Power: 27.0 kW (112.5A) UEF: 0.99 Energy Factor Fuel: ELECTRIC

High-power whole-house electric unit (Requires 3x 40A double-pole breakers).

RHEEM Rheem RTEX-18 (240V)
1.8 GPM @ 70°F
Power: 18.0 kW (75A) UEF: 0.99 Energy Factor Fuel: ELECTRIC

Compact electric unit for 1-2 bathroom apartments or warm southern climates.

Climate Zone Sizing Matrix

1 Bed, 1 Bath Water Heater Specs by Region

Required heating capacity changes drastically depending on your local incoming groundwater temperature.

Cold Climate (North / Canada)
Inlet: 40°F Rise (ΔT): 80°F
Required Gas BTU 140,000 BTU/hr
Electric Power 20.5 kW
Recommended Unit Rating 4.5 GPM @ 35°F rise
Moderate Climate (Midwest / Mid-Atlantic)
Inlet: 55°F Rise (ΔT): 65°F
Required Gas BTU 114,000 BTU/hr
Electric Power 16.7 kW
Recommended Unit Rating 3.8 GPM @ 35°F rise
Warm Climate (South / Sunbelt)
Inlet: 70°F Rise (ΔT): 50°F
Required Gas BTU 87,500 BTU/hr
Electric Power 12.8 kW
Recommended Unit Rating 3.5 GPM @ 35°F rise
Fixture Demand Breakdown

Simultaneous Peak Load Calculation for 1 Bed, 1 Bath

How the 3.5 GPM peak simultaneous flow demand is calculated for 1 - 2 People:

  • 1 Main Shower (2.0 GPM)
  • 1 Kitchen Sink / Dishwasher (1.5 GPM)
Total Combined Simultaneous Flow: 3.5 Gallons Per Minute (13.2 L/min)
Natural Gas / Propane
1/2" or 3/4" Gas Line (Up to 140,000 BTU input)
Electrical Panel
100-150 Amp main panel (Minimum 2x 40A DP breakers for 18-20 kW)
Tank Water Heater Alternative
30 Gallon Storage Tank
Home Size Navigation

Compare Other Home Layout Sizing

Explore water heater sizing calculations for different bedroom and bathroom counts.

Expert FAQ Guide

1 Bed, 1 Bath Sizing FAQs

Common questions about water heater sizing for 1 bedroom homes.

2 Questions Answered
Q1 What size tankless water heater do I need for a 1 bedroom 1 bathroom home?

A 1 bed 1 bath house with 1-2 occupants needs a unit delivering at least 3.5 GPM at your local temperature rise. In cold climates, choose a 140k-160k BTU gas or 18-20 kW electric unit.

Q2 Can a 13 kW electric tankless water heater run a 1 bed 1 bath condo?

Only in warm climates (Florida, Texas, Southern CA) where ground water is 65°F+. In northern cold zones, a 13 kW unit will struggle during winter when incoming water is 40°F.

Copied to clipboard!