ASTM D1785 / Heavy Duty Schedule 80 True ID: 0.957" (24.31 mm) 630 PSI @ 73°F

1" Schedule 80 PVC Pipe Volume & Capacity Calculator

Standard 1" nominal Schedule 80 PVC pipe has an exact inside diameter of 0.957 inches, holding 0.0374 US gallons (0.464 liters per meter) per linear foot. Part of our PVC Pipe Volume Hub and universal Pipe Volume Calculator suite.

Presets:
Calculated Result

Total Liquid Capacity

Internal Holding Volume
0.7473 US gallons
≈ 2.829 litres

Unit Conversions

US Gallons 0.7473 gal
Litres 2.829 L
Cubic Feet (ft³) 0.0999 ft³
Cubic Inches (in³) 172.63 in³
Imperial Gallons 0.6223 UK gal
Cubic Meters (m³) 0.0028 m³
Filled Water Weight 6.2 lbs (2.8 kg)
Linear Capacity Rate 0.0374 gal/ft

Calculations are based on cylindrical formula \(V = \pi r^2 L\). Verify dimensions against manufacturer specs for code submittals.

Pre-Calculated Capacity Table

1" Schedule 80 PVC Quick Reference Sizing Chart

Instant capacity and weight lookup table for common pipe lengths filled with water at 60°F (15.5°C).

Pipe Length (Ft) US Gallons Liters Cubic Feet (ft³) Water Weight (lbs) Dry Pipe (lbs) Total Wet Weight
1 ft 0.037 gal 0.14 L 0.005 ft³ 0.3 lbs 0.4 lbs 0.7 lbs
2 ft 0.075 gal 0.28 L 0.010 ft³ 0.6 lbs 0.8 lbs 1.4 lbs
5 ft 0.187 gal 0.71 L 0.025 ft³ 1.6 lbs 2.0 lbs 3.6 lbs
10 ft 0.374 gal 1.41 L 0.050 ft³ 3.1 lbs 4.1 lbs 7.2 lbs
20 ft 0.748 gal 2.83 L 0.100 ft³ 6.2 lbs 8.1 lbs 14.3 lbs
50 ft 1.87 gal 7.1 L 0.25 ft³ 15.6 lbs 20.3 lbs 35.9 lbs
100 ft 3.74 gal 14.1 L 0.50 ft³ 31.2 lbs 40.5 lbs 71.7 lbs
250 ft 9.35 gal 35.4 L 1.25 ft³ 78.0 lbs 101.3 lbs 179.3 lbs
500 ft 18.70 gal 70.7 L 2.50 ft³ 156.0 lbs 202.5 lbs 358.5 lbs
Engineering Formula

How to Calculate 1" PVC Pipe Volume Manually

Step-by-step mathematical demonstration using cylinder geometric principles and ASTM D1785 specifications.

Step 1

Determine the Internal Radius (r)

Nominal size is 1", but true inner diameter is 0.957 inches.

r = ID / 2 = 0.957 / 2 = 0.4785"
Step 2

Calculate Cross-Sectional Area (A)

Compute circular cross-section area using $A = \pi \times r^2$:

A = \pi \times (0.4785)^2 = 0.7193 sq in
Step 3

Calculate Linear Foot Volume

Multiply cross-sectional area by 12 inches (1 linear foot):

V_linear = 0.7193 \times 12 = 8.632 cu in/ft
Step 4

Convert to US Gallons & Liters

Divide cubic inches by 231 (cubic inches in 1 US Gallon):

Gallons/Ft = 8.632 / 231 = 0.0374 Gal/Ft
Technical Specifications

1" Schedule 80 PVC Engineering Profile

Physical dimensions, pressure thresholds, and hydraulic velocity limits.

Outside Diameter (OD)
1.315 inches
33.4 mm
Inside Diameter (ID)
0.957 inches
24.31 mm
Wall Thickness
0.179 inches
ASTM D1785 Tolerance
Max Recommended Flow
11.2 GPM
At 5 ft/s velocity
Working Pressure
630 PSI
At 73°F (23°C)
Max Temperature Limit
140°F
60°C continuous

Common Plumbing & Piping Applications for 1" Schedule 80:

  • Industrial plating and processing
  • Corrosive wastewater lines
  • High pressure booster systems

Primary Use Case: Heavy-duty industrial water processing, commercial carwash pressure piping, and aggressive fluid handling.

Size Navigation

Compare Other PVC Pipe Sizes

Explore adjacent diameter calculations or compare with different pressure schedules.

Cross-Material Comparison

Compare 1" Pipe in Other Materials

Compare fluid holding capacity, wall thickness, and weight against other standard piping materials for 1" nominal diameter:

Copper Tubing (ASTM B88) 1" Copper (Type K/L/M) Cast Iron DWV (ASTM A888) Cast Iron Soil Pipe Schedule 40 Steel (ASTM A53) Steel Schedule 40 Pipe Fluid Velocity & GPM 1" Flow Rate Calculator
Expert FAQ Guide

1" Schedule 80 PVC FAQs

Frequently asked engineering and volumetric capacity questions for 1" PVC.

1 Questions Answered
Q1 How much water is in a 1-inch Schedule 80 PVC pipe per foot?

A 1" Schedule 80 PVC pipe holds 0.0374 US Gallons (0.1416 Liters) per linear foot.

Copied to clipboard!