ASTM D1785 / Heavy Duty Schedule 80 True ID: 1.939" (49.25 mm) 400 PSI @ 73°F

2" Schedule 80 PVC Pipe Volume & Capacity Calculator

Standard 2" nominal Schedule 80 PVC pipe has an exact inside diameter of 1.939 inches, holding 0.1534 US gallons (1.905 liters per meter) per linear foot. Part of our PVC Pipe Volume Hub and universal Pipe Volume Calculator suite.

Presets:
Calculated Result

Total Liquid Capacity

Internal Holding Volume
3.068 US gallons
≈ 11.613 litres

Unit Conversions

US Gallons 3.068 gal
Litres 11.613 L
Cubic Feet (ft³) 0.4101 ft³
Cubic Inches (in³) 708.69 in³
Imperial Gallons 2.555 UK gal
Cubic Meters (m³) 0.0116 m³
Filled Water Weight 25.6 lbs (11.6 kg)
Linear Capacity Rate 0.1534 gal/ft

Calculations are based on cylindrical formula \(V = \pi r^2 L\). Verify dimensions against manufacturer specs for code submittals.

Pre-Calculated Capacity Table

2" Schedule 80 PVC Quick Reference Sizing Chart

Instant capacity and weight lookup table for common pipe lengths filled with water at 60°F (15.5°C).

Pipe Length (Ft) US Gallons Liters Cubic Feet (ft³) Water Weight (lbs) Dry Pipe (lbs) Total Wet Weight
1 ft 0.153 gal 0.58 L 0.021 ft³ 1.3 lbs 0.9 lbs 2.2 lbs
2 ft 0.307 gal 1.16 L 0.041 ft³ 2.6 lbs 1.9 lbs 4.4 lbs
5 ft 0.767 gal 2.90 L 0.103 ft³ 6.4 lbs 4.7 lbs 11.1 lbs
10 ft 1.534 gal 5.81 L 0.205 ft³ 12.8 lbs 9.4 lbs 22.1 lbs
20 ft 3.068 gal 11.61 L 0.410 ft³ 25.6 lbs 18.7 lbs 44.3 lbs
50 ft 7.67 gal 29.0 L 1.03 ft³ 63.9 lbs 46.8 lbs 110.8 lbs
100 ft 15.34 gal 58.1 L 2.05 ft³ 127.9 lbs 93.6 lbs 221.5 lbs
250 ft 38.35 gal 145.2 L 5.13 ft³ 319.8 lbs 234.0 lbs 553.8 lbs
500 ft 76.70 gal 290.3 L 10.25 ft³ 639.5 lbs 468.0 lbs 1107.5 lbs
Engineering Formula

How to Calculate 2" PVC Pipe Volume Manually

Step-by-step mathematical demonstration using cylinder geometric principles and ASTM D1785 specifications.

Step 1

Determine the Internal Radius (r)

Nominal size is 2", but true inner diameter is 1.939 inches.

r = ID / 2 = 1.939 / 2 = 0.9695"
Step 2

Calculate Cross-Sectional Area (A)

Compute circular cross-section area using $A = \pi \times r^2$:

A = \pi \times (0.9695)^2 = 2.9529 sq in
Step 3

Calculate Linear Foot Volume

Multiply cross-sectional area by 12 inches (1 linear foot):

V_linear = 2.9529 \times 12 = 35.435 cu in/ft
Step 4

Convert to US Gallons & Liters

Divide cubic inches by 231 (cubic inches in 1 US Gallon):

Gallons/Ft = 35.435 / 231 = 0.1534 Gal/Ft
Technical Specifications

2" Schedule 80 PVC Engineering Profile

Physical dimensions, pressure thresholds, and hydraulic velocity limits.

Outside Diameter (OD)
2.375 inches
60.3 mm
Inside Diameter (ID)
1.939 inches
49.25 mm
Wall Thickness
0.218 inches
ASTM D1785 Tolerance
Max Recommended Flow
46 GPM
At 5 ft/s velocity
Working Pressure
400 PSI
At 73°F (23°C)
Max Temperature Limit
140°F
60°C continuous

Common Plumbing & Piping Applications for 2" Schedule 80:

  • Industrial process manifolds
  • High-pressure chemical treatment
  • Commercial water park filtration

Primary Use Case: Heavy-duty pressure applications requiring enhanced impact resistance, higher burst pressures, and chemical durability.

Size Navigation

Compare Other PVC Pipe Sizes

Explore adjacent diameter calculations or compare with different pressure schedules.

Cross-Material Comparison

Compare 2" Pipe in Other Materials

Compare fluid holding capacity, wall thickness, and weight against other standard piping materials for 2" nominal diameter:

Copper Tubing (ASTM B88) 2" Copper (Type K/L/M) Cast Iron DWV (ASTM A888) Cast Iron Soil Pipe Schedule 40 Steel (ASTM A53) Steel Schedule 40 Pipe Fluid Velocity & GPM 2" Flow Rate Calculator
Expert FAQ Guide

2" Schedule 80 PVC FAQs

Frequently asked engineering and volumetric capacity questions for 2" PVC.

2 Questions Answered
Q1 How many gallons does 100 feet of 2" Schedule 80 PVC pipe hold?

A 100-foot run of 2-inch Schedule 80 PVC pipe holds 15.34 US Gallons (58.07 Liters) of water.

Q2 Why does 2" Schedule 80 hold less volume than 2" Schedule 40?

Both have identical outer diameters (2.375"), but Schedule 80 has a much thicker wall (0.218" vs 0.154"), reducing the inner diameter from 2.067" down to 1.939".

Copied to clipboard!